TM 1-1520-238-23
Change 8
16-67
16.14.
PYLON AERIAL BRACKET REMOVAL/INSTALLATION - continued
16.14.3. Removal
WARNING
Maintain pressure on preloaded
spring while removing retaining ring.
A spring-loaded mechanism can
cause injury to personnel if released
in an uncontrolled manner. Always
take care while working with the
mechanism.
a. Wrap lockwire around two springs (1) at three
places.
(1) Evenly space lockwire to hold spring (1) fully
compressed. Use wire (item 229, App F).
b. Remove connector P510 (2) and connector
P525 (3) from aerial bracket (4).
(1) Remove retaining ring (5), backing washer
(6), and spring (1) from connector P510 (2).
Use retaining ring pliers.
(2) Remove retaining ring (5), backing washer
(6) and spring (1) from connector P525 (3).
Use retaining ring pliers.
(3) Remove connector P510 (2), connector P525
(3), and retaining rings (7) from bracket (4).
c. Remove clamps (8) and (9) from bracket (4).
(1) Remove two screws (10) and washers (11).
(2) Remove clamps (8) and (9).
d. Remove circuit card (12) from bracket (4).
(1) Remove two screws (13) and washers (14).
(2) Remove circuit card (12).
GO TO NEXT PAGE
5
6
1
4
7
2
1
3
6
5
M04-2712-3
M04-2712-4A
8
11
10
4
9
11
10
M04-2712-5A
14
13
12
4