TM 11520238T1
464
Change 5
49
PNVS INTERACTIVE FD/LS CHECK (cont)
49
TASK
RESULT
When the response is
acknowledged (ACK) press
and release ENTER SPACE
(ADC) or SPC (ADD) key
ONLY if prompt does not
change.
Refer to TM 1-5855-265-T for
descriptions of and remarks
about this message and
these prompts.
If one or more FD/LS
NOGO displays listed
appear on HOD, perform the
following in sequence:
(1) Perform SYSTEMS
POWER DOWN
(para 32)
(2) Perform CORRECTIVE
ACTION indicated for first
NOGO displayed on
HOD.
(3) Perform SYSTEMS
POWERUP
(para 31).
(4) Repeat FD/LS check
beginning with step 2. If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 1-5855-265-T.
If no failures are detected,
the automatic part of initiated
BIT is exited and prompt
ARE OPERATOR
INTERACTIVE TESTS
REQUIRED?(Y/N) appears
on HOD. Go to next step.