TM 11520238T1
460
49
PNVS INTERACTIVE FD/LS CHECK (cont)
49
NOTE
Pause 60 seconds before proceeding to set the
ACM switch to ACM. PNVS requires 60
seconds for gyro runup before PNVS turret
assembly can be commanded out of the stow
position.
Pilot Station (fig. 21)
PANEL
SWITCH/CONTROL
POSITION
(set to)
FIRE
SIGHT SEL
STBY
CONTROL
ACQ SEL
NVS FXD
(fig. 22)
VID SEL
PLT
PNVS
PNVS
FIRE
CONTROL
(fig. 22)
ACM
ACM
WARNING
Personnel are not allowed closer than 3 feet
from an energized PNVS or TADS system. A
turret assembly rotating under power has
enough force to cause bodily injury.
CAUTION
If PNVS turret assembly does not come out
of the stow position, quickly open
MISSION/PNVS AC and MISSION/PNVS DC
circuit breakers. Failure to comply may
result in damage to drive motor.
SIGHT SEL
NVS
COLLECTIVE
NVS
PNVS
CONTROL
PLRT/BRSIT HMD
center (off)
STICK
(fig. 224)
ANTI ICE
(fig. 222)
TADS/PNVS
GND