414 TADS INTERACTIVE FD/LS CHECK (cont)
414
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
ORT COLUMN ASSY
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
ORT column assembly
(TM 1-1270-476-20).
TADS AC TORQUER
AMP NOGO TURRET
BULKHEAD (ACY)
Refer to TM 9-1270-476-30,
and troubleshoot the TADS
turret assembly.
TADS TURRET ASSY
NOGO TURRET
BULKHEAD (ACZ)
Refer to TM 9-1270-476-30,
and troubleshoot the TADS
turret assembly.
TADS TV SENSOR
NOGO DSA
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
television (TV) sensor
assembly
(TM 1-1270-476-20).
ORT HOD CONTROLS
NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
control panel assembly
(TM 1-1270-476-20).
ORT HOD LEFT HAND
GRIP NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace left
hand grip assembly
(TM 1-1270-476-20).