414 TADS INTERACTIVE FD/LS CHECK (cont)
414
FD/LS NOGO
DISPLAY
CORRECTIVE ACTION
AND NOGO CPG
COMPARTMENT
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
alphanumeric display (AND)
assembly
(TM 1-1270-476-20).
TADS LASER
TRANSCEIVER
NOGO DSA
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
TADS laser transceiver unit
(LTU) assembly
(TM 1-1270-476-20).
TADS LASER
ELECTRONICS
NOGO LH FAB
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO,
replaceTADS laser
electronics unit (LEU)
(TM 1-1270-476-20).
TADS POWER
SUPPLY NOGO LH
FAB
Check fuses F1, F2, and F3.
If any fuses are bad, replace
fuse(s) and repeat FD/LS
check. If fuses are good,
troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
TADS power supply (TPS)
(TM 1-1270-476-20).
TADS ELECTRONIC
UNIT NOGO LH FAB
Troubleshoot wiring to isolate
fault (TM 1-1270-476-T). If
troubleshooting does not
remove NOGO, replace
TEU assembly
(TM 1-1270-476-20).