TM 11520238T1
Change 5
4117
417 APU INTERACTIVE FD/LS CHECK (cont)
417
TASK
RESULT
(1) Perform SYSTEMS
POWER DOWN
(para 32) and APU
shutdown (para 33).
(2) Perform CORRECTIVE
ACTION indicated for first
NOGO displayed on
HOD.
(3) Perform SYSTEMS
POWERUP
(para 31).
(4) On DEK, rotate DATA
ENTRY switch to STBY
for 5 seconds, then back
to FD/LS (ADC).
(5) Repeat FD/LS check
beginning with step b .If
NOGO repeats after
CORRECTIVE ACTION,
refer to
TM 1-1520-238-T-8.
NOTE
Record all NOGOs before rotating DATA
ENTRY switch to STBY (ADC).
f. On DEK, rotate
DATA ENTRY switch
to STBY (ADC).
NOTE
After APU startup has been initiated and no
failures detected within a 90second period
has elapsed, the advisory message APU GO
ANY KEY FOR FDLS MENUS appears on
the HOD.
If this FD/LS check is to be followed by a
APU OPERATIONAL CHECK
(TM 1-1520-238-T-8), omit step 3.
3. Perform SYSTEMS POWER DOWN (para 32) and
APU shutdown (para 33) if power no longer required.