TM 11520238T3
96
920 SIGNAL NAME:
LH FAB MRTU TYPE I INPUT BIT STATUS
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
14
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates status of turnon test of input circuitry.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If second digit on HOD is 7, go to paragraph 921.
FAIL: Location of fault: MUX FAB L circuit breaker, wiring from MUX FAB L circuit breaker to LH FAB
MRTU Type I, LH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
921 SIGNAL NAME:
LH FAB MRTU TYPE I AD BIT STATUS
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
13
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates selftest status of analog to digital converter.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If third digit on HOD is 1, go to paragraph 922.
FAIL: Location of fault: MUX FAB L circuit breaker, wiring from MUX FAB L circuit breaker to LH FAB
MRTU Type I, LH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
922 SIGNAL NAME:
LH FAB MRTU TYPE I SERIAL DIGITAL ERROR
MEMORY LOCATION: 001062
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors target acquisition designation sight (TADS).
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
Location of fault if fourth digit on HOD is 0: replace FCC (TM 91230476201).
FAIL: Location of fault: go to Chapter 15, paragraph 1527.
923 SIGNAL NAME:
LH FAB MRTU TYPE I SERIAL DIGITAL ERROR
MEMORY LOCATION: 001124
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors rounds counter controller.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If fourth digit on HOD is 0, go to paragraph 924.
FAIL: Location of fault: go to Chapter 5, paragraph 58.
924 SIGNAL NAME:
LH FAB MRTU TYPE I SERIAL DIGITAL ERROR
MEMORY LOCATION: 001157
MEMORY DATA BIT(S):
10
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Monitors rounds counter controller.
REMARKS: From LH FAB MRTU Type I to FCC.
PASS:
If fourth digit on HOD is 0, go to paragraph 925.
FAIL: Location of fault: go to Chapter 5, paragraph 58.