TM 11520238T3
98
930 SIGNAL NAME:
RH FAB MRTU TYPE I STATUS WORD BBC STATUS BIT
MEMORY LOCATION: 001517
MEMORY DATA BIT(S):
18
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates selftest status of the BBC.
REMARKS: From RH FAB MRTU Type I to FCC.
PASS:
If first digit on HOD is 2 or 6, go to paragraph 931.
FAIL: Location of fault: MUX FAB R circuit breaker, wiring from MUX FAB R circuit breaker to RH
FAB MRTU Type I, RH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
931 SIGNAL NAME:
RH FAB MRTU TYPE I STATUS WORD OUTPUT CLEAR
MEMORY LOCATION: 001517
MEMORY DATA BIT(S):
17
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates all MRTU outputs are cleared.
REMARKS: From RH FAB MRTU Type I to FCC.
PASS:
If first digit on HOD is 6, go to paragraph 932.
FAIL: Location of fault: MUX FAB R circuit breaker, wiring from MUX FAB R circuit breaker to RH
FAB MRTU Type I, RH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
932 SIGNAL NAME:
RH FAB MRTU TYPE I STATUS DISCRETE OUTPUT BIT
MEMORY LOCATION: 001517
MEMORY DATA BIT(S):
16
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates selftest status of 5 VDC discrete outputs.
REMARKS: From RH FAB MRTU Type I to FCC.
PASS:
If second digit on HOD is 1, 3, 5, or 7, go to paragraph 933.
FAIL: Location of fault: MUX FAB R circuit breaker, wiring from MUX FAB R circuit breaker to RH
FAB MRTU Type I, RH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).
933 SIGNAL NAME:
RH FAB MRTU TYPE I STATUS DC ANALOG OUTPUT BIT
MEMORY LOCATION: 001517
MEMORY DATA BIT(S):
15
(BINARY)
CONDITION:
(None)
SIGNAL FUNCTION:
Indicates state of output DC analog circuits.
REMARKS: From RH FAB MRTU Type I to FCC.
PASS:
If second digit on HOD is 3 or 7, go to paragraph 934.
FAIL: Location of fault: MUX FAB R circuit breaker, wiring from MUX FAB R circuit breaker to RH
FAB MRTU Type I, RH FAB MRTU Type I. Troubleshoot wiring to isolate fault
(TM 91230476202).