TM 11520238T3
1520
1575 SIGNAL NAME:
AND L1 CHAR 20 19
MEMORY LOCATION: 000606
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 19 and 20 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1576.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1576 SIGNAL NAME:
AND L1 CHAR 22 21
MEMORY LOCATION: 000605
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 21 and 22 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1577.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1577 SIGNAL NAME:
AND L1 CHAR 24 23
MEMORY LOCATION: 000604
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 23 and 24 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1578.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1578 SIGNAL NAME:
AND L2 CHAR 2 1
MEMORY LOCATION: 000603
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 1 and 2 on line 2.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1579.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1579 SIGNAL NAME:
AND L2 CHAR 4 3
MEMORY LOCATION: 000602
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 3 and 4 on line 2.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1580.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).