TM 11520238T3
1519
1570 SIGNAL NAME:
AND L1 CHAR 10 9
MEMORY LOCATION: 000613
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 9 and 10 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1571.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1571 SIGNAL NAME:
AND L1 CHAR 12 11
MEMORY LOCATION: 000612
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 11 and 12 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1572.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1572 SIGNAL NAME:
AND L1 CHAR 14 13
MEMORY LOCATION: 000611
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 13 and 14 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1573.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1573 SIGNAL NAME:
AND L1 CHAR 16 15
MEMORY LOCATION: 000610
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 15 and 16 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1574.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).
1574 SIGNAL NAME:
AND L1 CHAR 18 17
MEMORY LOCATION: 000607
MEMORY DATA BIT(S):
419
(ASCII)
CONDITION:
Refer to Table 151 for ASCII code conversions.
SIGNAL FUNCTION:
Converts 16bit word to characters 17 and 18 on line 1.
REMARKS: From FCC through CPG MRTU Type III to AND.
PASS:
If ASCII conversion results correspond to display on HOD, go to paragraph 1575.
FAIL: Location of fault: AND, wiring from AND to CPG MRTU Type III, CPG MRTU Type III.
Troubleshoot wiring to isolate fault (TM 11270476T).