TM 1-1520-238-T-4
Change 5
682.15
620.1. HOD XMN 1 READING DISPLAYS 31 C TEMPERATURE
620.1
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 55-1500-323-24
TM 9-1230-476-20-2
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200 access panel and aft
avionics bay door open.
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
NOTE
A 32 C reading is caused by no
power to the transducer (MT13) or no
signal from the transducer to the
DASEC (A69).
If all HOD temperatures are 32 C and
ENG START circuit breaker is open,
troubleshoot with paragraph 622.2
before proceeding.
Entry in ( ) following pin locations is
multimeter lead orientation.
1. Detach P755. Check for open between:
P7552 and P7556 (red/blk),
P75510 and P75511 (red/blk).
Does open exist?
YES
Go to step 3.
NO
Go to step 2.
2. Check for short between:
P7552 and ground,
P75510 and ground.
Does short exist?
YES
Go to step 3.
NO
Go to step 4.
3. Locate open or short in wire harness between
P755 and MT13.
Can wire harness be repaired?
YES
Repair wiring
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Replace MT13
(TM 1-1520-238-23).
Go to paragraph 613.
4. Detach P682. Check for short between:
P68287 and ground.
Does short exist?
YES
Repair shorted wire between:
P68287 and ground
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Go to step 5.
5. Reconnect P755. Check for open between:
P68286 and P68287 (blk/red).
Does open exist?
YES
Repair open wire
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
END OF TASK