TM 1-1520-238-T-4
Change 5
682.17
621.
HOD XMN 2 READING DOES NOT DISPLAY AMBIENT TEMPERATURE
621
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 1-1520-238-T-6
TM 55-1500-323-24
TM 9-1230-476-20-2
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
L200 and R200 access
panels and aft avionics bay
door open.
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
NOTE
Transmission will display higher than
ambient temperature if recently
operated.
Entry in ( ) following pin locations is
multimeter lead orientation.
1. Detach P755. Check for open between:
P7553 and P7555 (red/blk),
P7557 and P7558 (red/blk).
Does open exist?
YES
Go to step 3.
NO
Go to step 2.
2. Check for short between:
P7553 and ground,
P7555 and ground,
P7557 and ground,
P7558 and ground.
Does short exist?
YES
Go to step 3.
NO
Go to step 4.
3. Locate open or short in wire harness between
P755 and MT14.
Can wire harness be repaired?
YES
Repair wiring
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Replace MT14
(TM 1-1520-238-23).
Go to paragraph 613.
4. Detach P682. Check for short between:
P68284 and ground,
P68285 and ground.
Does short exist?
YES
Repair shorted wire between:
P68284 and ground,
P68285 and ground
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Go to step 5.
5. Reconnect P755. Check for open between:
P68284 and P68285 (blk/red).
Does open exist?
YES
Repair open wire
(TM 55-1500-323-24).
Go to paragraph 613.
NO
Refer to TM 9-1230-476-20-2 to
troubleshoot multiplex
subsystem.
END OF TASK