TM 1-1520-238-T-5
8177
895.
CPG BAROMETRIC ALTIMETER EDGELIGHTING DOES NOT LIGHT
895
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Close CPG PRI LT circuit breaker.
Check for 5 VDC between (A326):
J14B11 and J14B12.
Is voltage present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for 5 VDC at
(A326)TB143F.
Is voltage present?
YES
Repair open wire between
(A326):
J14B12 and TB142F,
J14B11 and TB143F.
Go to paragraph 891.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
3. Check for 5 VDC between
P1191 and P1192.
Is voltage present?
YES
Replace CPG barometric
altimeter (TM 1-1520-238-23).
NO
Repair open wire between:
P473B4 and P1191,
P473B3 and P1192.
Go to paragraph 891.
END OF TASK