TM 1-1520-238-T-5
8180
898.
PILOT BAROMETRIC ALTIMETER EDGELIGHTING DOES NOT LIGHT
898
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Close pilot LT PRI circuit breaker.
Check for 5 VDC between (A326):
J17B1 and J17B2.
Is voltage present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for 5 VDC at
(A326)TB133F.
Is voltage present?
YES
Repair open wire between
(A326):
J17B1 and TB133F,
J17B2 and TB134F.
Go to paragraph 891.
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
3. Check for 5 VDC between
P382X and P382Y.
Is voltage present?
YES
Replace pilot barometric
altimeter (TM 1-1520-238-23).
NO
Repair open wire between:
P468B1 and P382Y,
P468B2 and P382X.
Go to paragraph 891.
END OF TASK