TM 1-1520-238-T-5
8181
899.
PILOT VSI EDGELIGHTING DOES NOT LIGHT
899
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Close pilot LT PRI circuit breaker.
Check for 5 VDC between (A326):
J16B13 and J16B14.
Is voltage present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for 5 VDC at
(A326)TB133E.
Is voltage present?
YES
Repair open wire between
(A326):
J16B13 and TB133E,
J16B14 and TB134E.
Go to paragraph 891,
or
replace resistor (A326)R24
(TM 1-1520-238-23).
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
3. Check for 5 VDC between
P1202 and P1203.
Is voltage present?
YES
Replace pilot vertical speed
indicator. (TM 1-1520-238-23).
NO
Repair open wire between
(A326):
P480B14 and P1203,
P480B13 and P1202.
Go to paragraph 891.
END OF TASK