TM 1-1520-238-T-5
8182
8100. PILOT SAI EDGELIGHTING DOES NOT LIGHT
8100
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot center circuit breaker panel, close LT
PRI circuit breaker. Check for 5 VDC between
(A326): J9A19 and J9A20.
Is voltage present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for 5 VDC at (A326)TB135G.
Is voltage present?
YES
Repair open wire between
(A326):
J9A20 and TB136G,
J9A19 and TB135G.
Go to paragraph 891,
or
replace resistor (A326)R7
(TM 1-1520-238-23).
NO
Refer to TM 1-1520-238-T-6 to
troubleshoot pilot edgelights.
3. Check for 5 VDC between
P383D and P383E.
Is voltage present?
YES
Replace SAI
(TM 1-1520-238-23).
NO
Repair open wire between:
P487A19 and P383D,
P487A20 and P383E.
Go to paragraph 891.
END OF TASK