TM 1-1520-238-T-5
8185
8103. PILOT BAROMETRIC ALTIMETER INTERNAL VIBRATOR IS NOT HEARD
8103
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer (2)
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Nontransparent
barrier removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 28 VDC at P382P.
Is voltage present?
YES
Go to step 4.
NO
Go to step 2.
2. Check for open between
P382P and P468B3.
Does open exist?
YES
Repair open wire.
Go to paragraph 891.
NO
Go to step 3.
3. Check for open between (A326):
J17B3 and J16A7.
Does open exist?
YES
Repair open wire between
(A326):
J17B3 and TB113K,
TB113L and J16A7.
Go to paragraph 891.
NO
Repair open wire between
P480A7 and P750 SP2.
Go to paragraph 891.
4. Check for open between
P382M and ground.
Does open exist?
YES
Repair open wire.
Go to paragraph 891.
NO
Replace pilot barometer
altimeter (TM 1-1520-238-23).
END OF TASK