TM 1-1520-238-T-6
9493
9223. MISSION ARM CONTR CIRCUIT BREAKER (CB46) DOES NOT STAY CLOSED OR
9223
28 VDC IS NOT PRESENT AT P2-E
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
TM 9-1090-208-23-2
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does MISSION ARM CONTR circuit breaker
(CB46) stay closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB46 and set BATT/EXT PWR switch to
OFF. Check for short between P2-E and ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 9-1090-208-23-2 to
troubleshoot external stores
control system.
3. Detach wire at CB46-2. Check for short between
P2-E and ground.
Does short exist?
YES
Repair shorted wire between
CB46-2 and P2-E.
Go to paragraph 9220.
NO
Replace MISSION ARM
CONTR circuit breaker (CB46)
(TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between:
CB46-1 and P4-J,
CB46-2 and P2-E.
Does open exist?
YES
Repair open wire.
Go to paragraph 9220.
NO
Replace MISSION ARM
CONTR circuit breaker (CB4)
(TM 1-1520-238-23.).
END OF TASK