9226. MISSION JETT CIRCUIT BREAKER (CB89) DOES NOT STAY CLOSED
9226
OR 28 VDC IS NOT PRESENT AT P1-18
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
TM 1-1520-238-T-8
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. On pilot ELEC PWR panel, set BATT/EXT PWR
switch to EXT PWR.
Does MISSION JETT circuit breaker (CB89)
stay closed?
YES
Go to step 4.
NO
Go to step 2.
2. Open CB89 and set BATT/EXT PWR switch to
OFF. Check for short between P1-18 and
ground.
Does short exist?
YES
Go to step 3.
NO
Refer to TM 1-1520-238-T-8 to
troubleshoot external stores
jettison system.
3. Detach wire at CB89-2. Check for short between
P1-18 and ground.
Does short exist?
YES
Repair shorted wire between
CB89-2 and P1-18.
Go to paragraph 9220.
NO
Replace MISSION JETT circuit
breaker (CB89)
(TM 1-1520-238-23).
4. Set BATT/EXT PWR switch to OFF. Check for
open between CB89-1 and CB49-1.
Does open exist?
YES
Go to step 5.
NO
Replace MISSION JETT circuit
breaker (CB89)
(TM 1-1520-238-23).
5. Check for open between CB89-2 and P1-18.
Does open exist?
YES
Repair open wire.
Go to paragraph 9220.
NO
Repair open wire between
CB91-1 and CB89-1. Go to
paragraph 9220.
END OF TASK