TM 1-1520-238-T-6
9699
9364. CPG CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK (cont)
9364
M69-335
PRI MUX INDICATOR
GUN INDICATOR
ROCKET INDICATOR
MISSILE INDICATOR
ADS INDICATOR
TADS INDICATOR
Figure 9235.
Pilot Caution/Warning Panel
Task
Result
n. On pilot caution/warning panel (fig. 9235),
check that ROCKET indicator is lighted. On
CPG FIRE CONTROL panel (fig. 9234),
set RKT switch to GND STOW.
If pilot ROCKET indicator is not lighted, replace lamp
(TM 1-1520-238-23). If lamp still does not light, go to
paragraph 9387.
o. On CPG FIRE CONTROL panel, set GUN
switch to NORM. On ORT, set WAS to GUN
position. On CPG caution/warning panel
(fig. 9232), check that GUN indicator is
lighted.
If CPG GUN indicator is not lighted, replace lamp
(TM 1-1520-238-23). If lamp still does not light, go to
paragraph 9388.
p. On pilot caution/warning panel, check that
GUN indicator is lighted. On CPG FIRE
CONTROL panel, set GUN switch to FXD.
If pilot GUN indicator is not lighted, replace lamp
(TM 1-1520-238-23). If lamp still does not light, go to
paragraph 9389.