9364. CPG CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK (cont)
9364
M69-336
WAS
SWITCH
Figure 9236.
CPG ORT
Task
Result
q. On CPG FIRE CONTROL panel
(fig. 9234), set MSL switch to ON. Set
WAS to MSL. On CPG caution/warning
panel (fig. 9232), check that MISSILE
indicator is lighted.
If CPG MISSILE indicator is not lighted, replace lamp
(TM 1-1520-238-23). If lamp still does not light, go to
paragraph 9390.
r. On pilot caution/warning panel (fig. 9235),
check that MISSILE indicator is lighted. On
CPG FIRE CONTROL panel, set MSL
switch to OFF.
If pilot MISSILE indicator is not lighted, replace lamp
(TM 1-1520-238-23). If lamp still does not light, go to
paragraph 9391.
s. On CPG FIRE CONTROL panel, set
FCC/MUX switch to OFF, CPG ARM switch
to OFF, and PLT/GND ORIDE switch to
OFF.
t. On CPG circuit breaker panel 1 (fig. 9228),
open FC FCC DC circuit breaker (CB4). On
CPG FIRE CONTROL panel (fig. 9234),
set MUX switch to SEC. On CPG
caution/warning panel, check that PRI MUX
indicator is lighted and flashing.
If PRI MUX indicator is not lighted and flashing,
replace lamp (TM 1-1520-238-23). If lamp still does
not light, go to paragraph 9392.
u. On CPG master caution/warning panel
(fig. 9231), press MASTER CAUTION
indicator. Check that MASTER CAUTION
indicator is not lighted.
If MASTER CAUTION is lighted, go to
paragraph 9393.