TM 1-1520-238-T-6
9701
9364. CPG CAUTION AND WARNING SYSTEM MAINTENANCE OPERATIONAL CHECK (cont)
9364
Task
Result
v. On CPG caution/warning panel (fig. 9232),
check that PRI MUX indicator is lighted and
not flashing.
If PRI MUX indicator is flashing, go to
paragraph 9393.
w. On pilot caution/warning panel (fig. 9235),
check that PRI MUX indicator is lighted and
not flashing.
If PRI MUX indicator is not lighted and flashing,
replace lamp (TM 1-1520-238-23). If lamp still does
not light, go to paragraph 9394.
2. Perform EXTERNAL POWER POWER DOWN (para 946).
END OF TASK