TM 1-1520-238-T-7
11124
1117.
TRIM CIRCUIT BREAKER DOES NOT STAY CLOSED FORCE TRIM OFF
1117
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Electrical power
distribution box cover
removed
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Detach wire from (A402)TB37/8B. Check for
short between J113A10 and ground.
Does short exist?
YES
Repair shorted wire between:
J113A10 and P423B16,
(A402)J11B16 and
(A402)TB37/8B.
Go to paragraph 1112.
NO
Go to step 2.
2. Check for short between (A401)P113A10 and
ground.
Does short exist?
YES
Replace pilot cyclic stick
(TM 1-1520-238-23).
NO
Go to paragraph 1116.
END OF TASK