TM 1-1520-238-T-7
11122
1116.
TRIM CIRCUIT BREAKER DOES NOT STAY CLOSED FORCE TRIM ON
1116
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Extractor, Relay
CTJ-RO6
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-T-6
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open TRIM circuit breaker (CB87). Check for
short between (A76)J1Y and ground.
Does short exist?
YES
Refer to TM 1-1520-238-T-6 to
troubleshoot circuit protection
system (dc emergency bus
pilot station).
NO
Go to step 2.
2. Detach P441. Check for short between P463Y
and ground.
Does short exist?
YES
Repair shorted wire between
P441B10 and P463Y.
Go to paragraph 1112.
NO
Go to step 3.
3. Detach wires from (A402): TB39G, TB39H,
and TB39J. Check for short between (A402):
J24A14 and ground,
J18A13 and ground,
J18A14 and ground.
Does short exist?
YES
Go to step 4.
NO
Go to step 5.
4. Detach wires from (A402): TB39G, TB39J,
and TB39H. With relay (A402)XK9/10
removed, check for short between (A402):
J24A14 and ground,
J18A13 and ground,
J18A14 and ground,
wire ends from:
TB39G and ground,
TB39H and ground,
TB39J and ground.
Does short exist?
YES
Repair shorted wire between
(A402):
J24A14 and K19/10A3,
J18A13 and K19/10B3,
J18A14 and K19/10C3,
TB39G and K19/10C2,
TB39H and K19/10B2,
TB39J and K19/10A2.
Go to paragraph 1113.
NO
Replace relay (A402)XK9/10
(TM 1-1520-238-23).
5. Detach wires from (A402): TB39K, TB39L
and TB39M. Check for short between (A402):
J11B6 and ground,
J11B7 and ground,
J24B10 and ground.
Does short exist?
YES
Repair shorted wire between
(A402):
J24B10 and TB39K,
J11B7 and TB39L,
J11B6 and TB39M.
Go to paragraph 1113.
NO
Go to step 6.