TM 1-1520-238-T-711–27411–51. BUCS ON INDICATORS – ARE NOT LIGHTED WITH BUCS TST SWITCH SET TO 11–51PLT OR CPG (cont)7. Check for open between P683–114 and P18–40.Does open exist?YESRepair open wire between:P18–40 and P908–A17,J908–A17 and J447–A20,P447–A20 and P683–114.Go to paragraph 11–23.NO(ACA) Replace DASEC(TM 1-1520-238-23).(ACB) Go to step 8.8. (ACB) Detach filter adapter A706. Check foropen through pin A706–114.Does open exist?YESReplace filter adapter(TM 1-1520-238-23).NOReplace DASEC(TM 1-1520-238-23).END OF TASK