TM 1-1520-238-T-7
Change 7
11325
1180.
DIR ACTUATOR NO-GO APPEARS ON HOD (cont)
1180
17. Check for 688 to 1032 ohms between:
(ACA) Wire ends (A323)TB36B and GS3H.
(ACB) P69317 and P69318.
Is resistance present?
YES
(ACB) Go to step 19.
(ACA) replace DASEC
(TM 1-1520-238-23).
NO
Go to step 18.
18. Check for open between:
(ACA) J2151 and (A323)TB36B,
J2152 and GS3H.
(ACB) J2151 and P69317,
J2152 and P69318.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace directional
servocylinder
(TM 1-1520-238-23).
19. (ACB) Detach filter adapter A708. Check for
open through pins:
A70827,
A70828,
A70842,
A70843,
A70855,
A70856.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Go to step 20.
20. Detach filter adapter A707. Check for open
through pins A70746 and A70747.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Go to step 21.
21. Detach filter adapter A706. Check for open
through pins:
A706105,
A706106,
A706111.
Does open exist?
YES
Replace filter adapter
(TM 1-1520-238-23).
NO
Go to step 22.
22. Has directional Linear Variable Differential
Transducer (LVDT) adjustment been performed?
YES
Replace DASEC
(TM 1-1520-238-23).
NO
Perform LVDT adjustment
(TM 1-1520-238-23).
END OF TASK