TM 1-1520-238-T-7
11329
1182. PILOT LONG LVDT NO-GO PLT COMPARTMENT APPEARS ON HOD
1182
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Place pilot cyclic stick to full forward or full aft.
Detach P688. Check for 10 VAC at P68815.
Is voltage present?
YES
(ACA) Replace DASEC
(TM 1-1520-238-23).
(ACB) Go to step 2.
NO
(ACA) Go to step 3.
(ACB) Go to step 4.
2. (ACB) Attach P688. Detach A708. Check for
10 VAC at A70815.
Is voltage present?
YES
(Replace DASEC
(TM 1-1520-238-23).
NO
(Replace filter adapter
(TM 1-1520-238-23).
3. (ACA) Check for short between:
P232C and ground,
P232D and ground.
Does short exist?
YES
Repair shorted wire between:
P232D and P912B9,
P232C and P912B10,
J912B9 and J459B8,
J912B10 and J459B9,
P459B8 and P68815,
P459B9 and P6888.
Go to paragraph 1123.
NO
Go to step 5.
4. (ACB) Check for short between:
J2323 and ground,
J2324 and ground.
Does short exist?
YES
Repair shorted wire between:
J2324 and P912B9,
J2323 and P912B10,
J912B9 and J459B8,
J912B10 and J459B9,
P459B8 and P68815,
P459B9 and P6888.
Go to paragraph 1123.
NO
Go to step 6.
5. (ACA) Check for open between:
P232C and P6888,
P232D and P68815.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 7.
6. (ACB) Check for open between:
J2323 and P6888,
J2324 and P68815.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to step 9.