TM 1-1520-238-T-7
11326
1181.
COLL ACTUATOR NO-GO APPEARS ON HOD
1181
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
References:
TM 1-1520-238-23
Equipment Conditions:
Ref
Condition
TM 1-1520-238-23
Access provisions
R295 door open
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Check for 1800 to 2200 ohms between P68859
and P68860.
Is resistance present?
YES
Go to step 3.
NO
Go to step 2.
2. Check for open between:
P2285 and P68859,
P2284 and P68860.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace collective servocylinder
(TM 1-1520-238-23).
3. Check for 90 to 100 ohms between:
(ACA) P683112 and P493B10.
(ACB) P683112 and ground.
Is resistance present?
YES
Go to step 5.
NO
Go to step 4.
4. Check for open between:
P683112 and P2282.
(ACA) P2289 and P493B10.
(ACB) P2289 and ground.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace collective servocylinder
(TM 1-1520-238-23).
5. Check for 90 to 100 ohms between P683108
and P683107.
Is resistance present?
YES
Go to step 7.
NO
Go to step 6.
6. Check for open between:
P683108 and P22810,
P683107 and P22811.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace collective servocylinder
(TM 1-1520-238-23).
7. Check for 364 to 424 ohms between P68829
and P68830.
Is resistance present?
YES
Go to step 9.
NO
Go to step 8.