TM 1-1520-238-T-7
11330
1182. PILOT LONG LVDT NO-GO PLT COMPARTMENT APPEARS ON HOD (cont)
1182
7. (ACA) Attach P688. Check for 26 VAC at
P232A.
Is voltage present?
YES
Go to step 8.
NO
Go to step 11.
8. (ACA) Check for open between P232B and
P493A18.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace pilot longitudinal (pitch)
LVDT
(TM 1-1520-238-23).
9. (ACB) Attach P688. Check for 26 VAC at
J2321.
Is voltage present?
YES
Go to step 10.
NO
Go to step 12.
10. (ACB) Check for open between J2322 and
P6946.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Replace pilot longitudinal (pitch)
LVDT
(TM 1-1520-238-23).
11. (ACA) Check for open between J232A and
P493A17.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1177.
12. (ACB) Check for open between J2321 and
P6945.
Does open exist?
YES
Repair open wire.
Go to paragraph 1123.
NO
Go to paragraph 1177.
END OF TASK