TM 1-1520-238-T-7
Change 5
11429
11128. MAN STAB MOVES DOWN BUT NOT UP
11128
Tools:
Nomenclature
Part Number
Tool Kit, Electrical
SC518099CLA06
Repairers
Multimeter, Digital
AN/PSM-45
Personnel Required:
68X
Armament/Electrical Systems Repairer
One person to assist
References:
TM 1-1520-238-23
WARNING
Turn off power before detaching or
attaching wires and connectors. High
current 28 VDC or 115 VAC is present.
Failure to do so could result in death or
serious injury.
1. Open STAB MAN DC (A76)CB6, STAB AUTO
DC (A76)CB3, STAB AUTO AC (A76)CB2, and
ENG WARN (A76)CB52 circuit breakers. Detach
P431 from (A402)J27.
Check for open between (A402):
TB221B and J27B10.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 2.
2. Detach P1077 from (A329)J1.
Check for open between P431B10 and
P1077L.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 3.
3. Check for open between (A329):
J1L and TB11/2C.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188.
NO
Go to step 4.
4. Set multimeter to diode setting. Place black
meter lead on (A329)TB11/2H.
Check for open between (A329):
TB11/2C and TB11/2H.
Does open exist?
YES
Repair open wire.
Go to paragraph 1188, or
replace diode
(TM 1-1520-238-23).
NO
Repair open wire between
(A329):
TB11/2H and TB13H.
Go to paragraph 1188.
END OF TASK