TM 1-1520-238-T-7Change 511–42911–128. MAN STAB MOVES DOWN BUT NOT UP11–128Tools:NomenclaturePartNumberTool Kit, ElectricalSC518099CLA06Repairer’sMultimeter, DigitalAN/PSM-45Personnel Required:68XArmament/Electrical Systems RepairerOne person to assistReferences:TM 1-1520-238-23WARNINGTurn off power before detaching orattaching wires and connectors. Highcurrent 28 VDC or 115 VAC is present.Failure to do so could result in death orserious injury.1. Open STAB MAN DC (A76)CB6, STAB AUTODC(A76)CB3, STAB AUTO AC(A76)CB2, andENG WARN(A76)CB52 circuit breakers. DetachP431 from (A402)J27.Check for open between (A402):TB2–21–B and J27–B10.Does open exist?YESRepair open wire.Go to paragraph 11–88.NOGo to step 2.2. Detach P1077 from (A329)J1.Check for open between P431–B10 andP1077–L.Does open exist?YESRepair open wire.Go to paragraph 11–88.NOGo to step 3.3. Check for open between (A329):J1–L and TB1–1/2–C.Does open exist?YESRepair open wire.Go to paragraph 11–88.NOGo to step 4.4. Set multimeter to diode setting. Place blackmeter lead on (A329)TB1–1/2–H.Check for open between (A329):TB1–1/2–C and TB1–1/2–H.Does open exist?YESRepair open wire.Go to paragraph 11–88, orreplace diode(TM 1-1520-238-23).NORepair open wire between(A329):TB1–1/2–H and TB1–3–H.Go to paragraph 11–88.END OF TASK