TM 1-1520-238-10
2-21
FIRE PULL handle will go out. If the fire is not extin-
guished, setting the switch at RES discharges the second
bottle. Bottle discharge is indicated on the FIRE TEST
panel by illumination of the PRI DISCH and RES DISCH
displays. The fire extinguishing equipment receives 28
vdc from the emergency dc bus through the PILOT, CPG
and APU FIRE EXTGH circuit breakers on the pilot over-
head circuit breaker panel.
2.18 FIRST AID KITS.
Two first aid kits are provided: one on the inside, aft por-
tion of the pilots right canopy panel and one on the lower
side of the CPG left console.
2.19 CHEMICAL, BIOLOGICAL, AND
RADIOLOGICAL (CBR) FILTER/BLOWER.
The CBR filter/blower provides filtered air to the flight crew
when cockpit air is contaminated. Each crew member car-
ries his own CBR blower/mask on board and connects it to
the external power source, located on the left side ar-
mored wing of his seat (fig 2-14).
Refer to TM 3-4240-312-12&P for CBR filter blower op-
eration, installation and maintenance instructions.
2.20 EMERGENCY PROCEDURES.
Chapter 9 describes emergency procedures.