TM 1-1520-238-23
2-171
2.56.
CPG STATION ACCESS DOOR MECHANISM REPAIR (AVIM) continued
j. Install strut pulley (42) with cable (21) on cyl-
inder (37).
(1) Feed cable (21) into cylinder (37).
(2) Aline strut pulley (42) with cylinder (37).
(3) Apply sealing compound to threads of screw
(43). Use sealing compound (item 169,
App F).
(4) Install two screws (43) through strut pulley
(42) and cylinder (37).
k. Install cylinder (37) on bracket (32).
(1) Install cylinder (37) and two bushings (41) in
bracket (32).
(2) Install pin (39) through bracket (32), two
bushings (41), cylinder (37), and washer (40).
(3) Install new cotter pin (38).
l. Install two pulleys (31) on bracket (32).
(1) Stack bushing (35), washer (36), pulley (31),
washer (36), pulley (31), washer (36), and
bushing (35) on 3/16 dowel (92). Use dowel.
(2) Feed cable (21) to upper pulley area.
(3) Install cable (21) around two pulleys (31).
(4) Install two pulleys (31), three washers (36),
and two bushings (35) in bracket (32).
(5) Install pin (34). Push dowel pin through.
(6) Install washer (36) on pin (34).
(7) Install new cotter pin (33).
GO TO NEXT PAGE
M04-1441-30
21
37
43
43
42
M04-1441-31
39
32
41
38
40
41
37
M04-1441-32
21
31
35
36
32
33
36
21
34
36
92
92
35