TM 1-1520-238-23
2-176
2.57.
CPG STATION ACCESS DOOR STRUT PULLEY REMOVAL/INSTALLATION continued
d. Remove nut (5) and screw (6) from cylinder
(1).
e. Swing out strut pulley (7) and remove from
twisted cable (8) and cylinder (1).
2.57.4. Cleaning
a. Clean sealing compound residue (para 1.47).
b. Wipe removed and attaching parts with a
clean rag.
2.57.5. Inspection
a. Check attaching points of cylinder for exces-
sive wear (para 2.11).
2.57.6. Installation
a. Install pulley (7) in cylinder (1).
(1) Install pulley (7) in twisted cable (8).
(2) Swing pulley (7) into cylinder (1).
b. Install screw (6) and nut (5) in cylinder (1).
(1) Apply sealing compound to threads of screw
(6). Use sealing compound (item 169,
App F).
(2) Install screw (6) and nut (5) in cylinder (1).
c. Install cylinder (1) on rod (2).
(1) Install cylinder (1), washer (4), and nut (3) on
rod (2).
d. Close CPG station access door.
e. Inspect (QA).
END OF TASK
5
1
6
M04-2707-3
1
8
7
M04-2707-4
1
5
6
M04-2707-5
M04-2707-6
1
4
3
2