TM 1-1520-238-23
2-178
Change 3
2.58.
CPG STATION ACCESS DOOR LOWER HINGE BUTT REMOVAL/INSTALLATION continued
2.58.4. Cleaning
a. Clean sealing compound residue (para 1.47).
b. Wipe removed and attaching parts and sur-
faces with a clean rag.
2.58.5. Inspection
a. Check hinge for damage (TM 1-1500-204-23).
b. Check mounting surfaces for cracks and cor-
rosion (para 2.12).
c. Check relative play across hinge pin.
(1) Maximum allowable play is 0.010 INCH.
2.58.6. Installation
a. Ensure door (1) is closed and latched.
b. Install hinge (2) on door (1).
(1) Aline hinge halves (2) and (9).
(2) Install hinge pin (4) (TM 1-1500-204-23).
(3) Locate and mark eight hole locations on
hinge (2) (TM 1-1500-204-23).
(4) Remove hinge pin (4) and lower hinge (2).
(5) Drill eight holes 0.313 to 0.319 INCH in diam-
eter through hinge (2).
(6) Apply sealant to threads of five screws (7)
and three screws (5). Use sealing compound
(item 176, App F) and brush (item 34,
App F).
(7) Install five screws (7) finger tight.
(8) Install three screws (5) and washers (6) finger
tight.
GO TO NEXT PAGE
7
5
M04-1442-3A
9
2
1
6
4
3