TM 1-1520-238-23
2-418.2
Change 2
2.114A. HORIZONTAL STABILATOR POSITION SENSOR CLAMP REPLACEMENT continued
2.114A.4. Cleaning
a. Wipe removed and attaching parts and sur-
faces with a clean rag.
2.114A.5. Inspection
a. Check removed and attaching parts for corro-
sion (para 1.49).
b. Check bracket for damage, cracks, and loose
or missing hardware.
(1) If bracket is damaged, fabricate (item D-232,
App
D)
and
replace
bracket
(TM 1-1500-204-23).
2.114A.6. Installation
a. Install clamp (1) on bracket (2).
(1) Aline clamp (1) on bracket (2).
(2) Install two bolts (3) through two washers (5),
clamp (1), bracket (2), and two washers (5).
(3) Install two nuts (4) on two bolts (3).
b. Install stabilator position transducer (para
11.231).
c. Inspect (QA).
END OF TASK
M04-5093-3
1
2
3
4
5
5