2.114.
HORIZONTAL STABILATOR ACTUATOR FITTING REMOVAL/INSTALLATION continued
2.114.6. Repair
CAUTION
Do not allow primer to enter bearing or
bearing contamination will result.
Installation pressure not to exceed 608
POUNDS or bearing damage will re-
sult.
Staking pressure not to exceed 13,000
POUNDS or bearing damage will re-
sult.
a. Repair fitting (1) by removing bearing (5).
(1) Remove and discard bearing (5) from fitting
(1) (TM 55-1500-322-24). Use arbor press
and puller kit.
(2) Clean fitting (1) bore and staking area. Use
methyl ethyl ketone (item 124, App F) and
cloth (item 52, App F).
(3) Coat fitting (1) bore and bearing (5). Use
primer (item 145, App F) and brush (item 34,
App F).
(4) Press wet bearing (5) into fitting (1) flush to
0.010 INCH above fitting surface
(TM 55-1500-322-24). Use arbor press.
NOTE
After bearing is installed it shall not be
possible to press bearing from housing
with finger.
(5) Form a neat fillet of excess primer around
outer race of bearing. Remove excess. Use
primer coating (item 147, App F).
GO TO NEXT PAGE
M04-4176-3
1
5