TM 1-1520-238-23
2-686
2.193.
WIRE STRIKE PROTECTION AIRCRAFT CABLE CUTTER REMOVAL/INSTALLATION
(AVIM) continued
2.193.3. Removal
a. If required, remove cutter support strut (1)
from aircraft cable cutter (2).
(1) Remove nut (3), two washers (4), and bolt
(5).
(2) Remove bolt (6) and washer (7).
(3) Remove strut (1) from cutter (2).
NOTE
Quantities of mounting hardware may
vary, depending on the cutter assembly.
b. Remove cutter (2) from upper fitting (8).
(1) Remove 6 nuts (9), 12 washers (10), and 6
bolts (11).
(2) Remove cutter (6) from fitting (8).
2.193.4. Cleaning
a. Clean sealing compound residue (para 1.47).
2.193.5. Inspection
a. Check cutter for bends, cracks, nicks, and
alinement. None allowed.
b. Check mounting surface for cracks, punc-
tures, corrosion, and loose or missing fasten-
ers (para 2.11).
c. Replace cutter blades which show evidence
of wire strike. Use existing hardware.
GO TO NEXT PAGE
3
4
5
1
11
10
8
7
2
M04-3543-1
UPPER
CUTTER
SHOWN
9
6
10