TM 1-1520-238-23
7-430
7.113.
HYDRAULIC TUBES AND FITTINGS PERMASWAGE REPAIR continued
7.113.7. Deburr Tube
CAUTION
Do not place fitting over tube end until
tube end is properly deburred. Damage
to the fitting may result.
a. Assemble correct deburring tool (8) and stem
(9).
Deburring
Tool
Tube OD
(Inch)
Tube Wall
Thickness
(Inch)
Stem
Required
D9851
1/4
1/16
3/8
0.016 - 0.028
0.028 - 0.050
0.016 - 0.035
0.016 - 0.035
0.035 - 0.058
D9851-13-04
D9851-13-03
D9851-13-05
D9851-13-06
D9851-13-07
D9850
1/2
5/8
3/4
0.016 - 0.042
0.042 - 0.065
0.016 - 0.058
0.016 - 0.065
D9850-13-08
D9850-13-09
D9850-13-10
D9850-13-12
D9849
1
1-1/4
1-1/2
0.020 - 0.083
0.024 - 0.065
0.065 - 0.109
0.028 - 0.083
D9849-13-06
D9849-13-20
D9849-13-21
D9849-13-24
GO TO NEXT PAGE
M04-2844-8
9
8