TM 1-1520-238-23
7-433
7.113.
HYDRAULIC TUBES AND FITTINGS PERMASWAGE REPAIR continued
RADIAL
MISMATCH
ANGULAR
MISMATCH
2º MAX
TUBE
SHORT
M04-2844-13
IF NECESSARY, PUSH
NEAR THE FIXED END OF
THE TUBE ASSEMBLY
SO THAT THE FREE
END IS CLEAR.
MEASURE MISMATCH
WITH THE FREE TUBE
END CLEAR OF THE FITTING.
MAX ALLOWABLE
1/32 INCH PER 10
INCHES OF TUBE
LENGTH FROM LAST
SUPPORT.
MAX ALLOWABLE
1/32 INCH PER 10 INCHES OF TUBE
LENGTH FROM LAST SUPPORT.
IF TUBE IS TOO LONG, EITHER:
REMOVE THE FITTING AND MEASURE THE CHANGE
IN POSITION OF THE FREE END: OR PUSH NEAR
THE FIXED TUBE END, AND MEASURE THE DISTANCE
TO JUST UNSEAT THE FREE END.
TUBE LONG
GO TO NEXT PAGE