7.113.
HYDRAULIC TUBES AND FITTINGS PERMASWAGE REPAIR continued
CAUTION
Do not place fitting over tube end until
tube is properly deburred. Damage to fit-
ting may result.
c. Trim, deburr and clean tube. Place fitting (15)
over tube to compare length with original fitting
and tube.
d. Install fitting and tube on aircraft. Position tube
in fitting, alining other end of tube with mating
tube. Remove and deburr trim. Clean ends as
required. Maximum gap allowed between mating
tubes is 0.300 INCH. See figure for allowable mis-
match.
GO TO NEXT PAGE
M04-2844-10
0.300" MAX.
15