TM 1-1520-238-23
Change 3 9-21
9.5.
PILOT CIRCUIT BREAKER PANEL HINGE STRAP REMOVAL/INSTALLATION continued
b. Remove hinge strap (8) from panel (2).
(1) Remove screw (9), washer (10), spacer (11),
strap (8), and self-locking nut (12) from panel
(2).
9.5.4. Cleaning
a. Wipe pilot circuit breaker panel mounting area
with a clean rag.
9.5.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.1).
b. Check
metallic
grommet
security
(TM 1-1500-204-23). Replace if loose.
c. Check removed and attaching parts for corro-
sion (para 1.49).
9.5.6. Installation
a. Attach strap (8) to panel (2).
(1) Install screw (9) through washer (10), spacer
(11), strap (8), and panel (2).
(2) Install nut (12) on screw (9).
b. Attach back cover (1) to panel (2).
(1) Position back cover (1) over stud (5).
(2) Install washer (4) and nut (3) on stud (5) on
top of back cover (1).
(3) Install three screws (6) through washers (7)
into bottom of back cover (1).
c. Inspect (QA).
d. Install pilot circuit breaker panel (para 9.3).
END OF TASK
M04-4189-3
12
11
10
9
8
2
M04-4189-4
11
12
2
8
10
9
7
6
3
4
5
M04-4189-5
2
1