TM 1-1520-238-23
9-57
9.17.
GENERATOR CONTROL UNIT (GCU) FIXED CAPACITOR REPLACEMENT (AVIM)
9.17.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.17.2. Initial Setup
Tools:
Electronic equipment maintenance kit (item 208,
App H)
Electrical tool kit (item 378, App H)
Light duty laboratory apron (item 27, App H)
Chemical protective gloves (item 154, App H)
Heat protective gloves (item 155, App H)
Electric gun type heater (item 163, App H)
Precision oven (item 221, App H)
Adjustable air filtering respirator (item 262, App H)
25-watt electric soldering iron (item 332, App H)
Materials/Parts:
Adhesive (item 8, App F)
Alcohol (item 25, App F)
Brush (item 35, App F)
Cloth (item 52, App F)
Gloves (item 83, App F)
Insulating compound kit (item 97, App F)
Insulation sleeving (item 102, App F)
Solder (item 189, App F)
Tape (item 202, App F)
Personnel Required:
39B
ATE Operator/Maintainer
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 11-6625-3085-30
TM 55-1500-323-24
Equipment Conditions:
Ref
Condition
9.15
Generator control unit (GCU) circuit card re-
moved
NOTE
This task is typical for capacitors C20,
C21, C22, and C23.
GO TO NEXT PAGE
M04-3705-1