TM 1-1520-238-23
9-61
9.17.
GENERATOR CONTROL UNIT (GCU) FIXED CAPACITOR REPLACEMENT (AVIM) continued
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
NOTE
If installing capacitor C23, perform step b.
If installing capacitors C20, C21, or C22,
proceed to step c.
b. Solder identified leads (1) and (2) to capacitor
C23 (3).
(1) Install sleeving (4) on identified lead (2). Use
insulation sleeving (item 102, App F)
(2) Solder identified leads (1) and (2) to capacitor
(3). Use solder (item 189, App F) and
soldering iron (TM 55-1500-323-24).
c. Solder identified leads (5) to capacitor (6).
(1) Solder identified leads (5) to capacitor C20,
C21, or C22 (6). Use solder (item 189, App F)
and soldering iron (TM 55-1500-323-24).
d. Perform appropriate test. Electronic Equipment
Test Facility (E.E.T.F) (TM 11-6625-3085-30).
GO TO NEXT PAGE
M04-3705-8
1
4
3
2
6
M04-3705-6
5