TM 1-1520-238-23
9-60
9.17.
GENERATOR CONTROL UNIT (GCU) FIXED CAPACITOR REPLACEMENT (AVIM) continued
9.17.4. Cleaning
a. Remove residual adhesive from capacitor
mounting area. Use alcohol (item 25, App F)
and cloth (item 52, App F).
9.17.5. Inspection
a. Check for removal of conformal coating and
adhesive. Use 10X stereo microscope from
electronic equipment maintenance kit.
b. Check capacitor mounting surface for dam-
age.
c. Check capacitor mounting surface for corro-
sion (para 1.49).
9.17.6. Installation
a. Bond capacitor (3) or (6) to control unit (7).
(1) Apply adhesive to capacitor (3) or (6). Use
adhesive (item 8, App F).
(2) Bond capacitor (3) or (6) to mounting surface
of control unit (7).
GO TO NEXT PAGE
3
M04-3705-5
6
7