TM 1-1520-238-23
9-59
9.17.
GENERATOR CONTROL UNIT (GCU) FIXED CAPACITOR REPLACEMENT (AVIM) continued
b. Remove coating from leads (5). Use brush
(item 35, App F).
c. Desolder leads (5) from capacitor (6).
(1) Identify and desolder leads (5) from capacitor
C20, C21, or C22 (6). Use soldering iron
(TM 55-1500-323-24).
d. Remove conformal coating from generator
control unit (7).
(1) Reduce coating around capacitor C23 (3),
C20, C21, or C22 (6). Use appropriate ball
mills from electrical maintenance kit.
(2) Remove existing coating around capacitor
C23 (3), C20, C21, or C22 (6). Use fine abra-
sive bullet wheel from electronic equipment
maintenance kit.
WARNING
Do not place heater near flammable
material or allow heater to contact
skin: severe burns can result. Wear
protective equipment. If injury occurs,
seek medical aid.
e. Remove capacitor (3) or (6) from generator
control unit (7).
(1) Weaken bond between capacitor C23 (3),
C20, C21, or C22 (6), and control unit (7).
Use heater.
(2) Pry between capacitor (3) or (6) and control
unit (7). Use non-metallic tool from electronic
equipment maintenance kit.
(3) Gently lift capacitor (3) or (6) from control unit
(7).
GO TO NEXT PAGE
M04-3705-3
MILL PERIMETER
OF CAPACITOR
5
6
7
3
M04-3705-4
7
6
3