TM 1-1520-238-23
9-90
9.25.
ELECTRICAL POWER DISTRIBUTION BOX POWER TRANSFORMER T3
REPLACEMENT continued
9.25.3. Removal
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
a. Desolder wires (1) from transformer (2).
(1) Identify
and
desolder
wires
(1)
(TM 55-1500-323-24). Use soldering iron.
b. Remove transformer (2) from support (3).
(1) Remove two screws (4) and washers (5).
(2) Remove and discard transformer (2).
9.25.4. Cleaning
a. Clean removed and attaching parts (para
1.47).
9.25.5. Inspection
a. Check removed and attaching parts for dam-
age (para 9.1).
b. Check electrical terminals for damaged
threads and loose mounting (para 9.1).
c. Check wiring for wear, cuts, breaks, cracked,
broken, or burned insulation (para 9.1).
d. Check removed and attaching parts for corro-
sion (para 1.49).
GO TO NEXT PAGE
2
3
5
4
M04-4523-3
1