TM 1-1520-238-23
9-91
9.25.
ELECTRICAL POWER DISTRIBUTION BOX POWER TRANSFORMER T3
REPLACEMENT continued
9.25.6. Installation
a. Install new transformer (2) on support (3).
(1) Position transformer (2) on support (3).
(2) Install two screws (4) and washers (5).
WARNING
Soldering iron can cause severe
burns to personnel and start fires.
Observe all safety precautions when
using soldering iron. If injury occurs,
seek medical aid.
b. Solder wires (1) to transformer (2).
(1) Solder
identified
wires
(1)
(TM 55-1500-323-24). Use soldering iron and
solder (item 189, App F).
c. Inspect (QA).
d. Install electrical power distribution box cover
(para 9.9).
END OF TASK
2
3
5
4
M04-4523-4
1