9.28.
ELECTRICAL TEST PANEL CIRCUIT BREAKER REPLACEMENT
9.28.1. Description
This task covers:
Removal. Cleaning. Inspection. Installation.
9.28.2. Initial Setup
Tools:
Electrical tool kit (item 378, App H)
Personnel Required:
68X
Armament/Electrical System Repairer
68X3F
Armament/Electrical System Repairer/
Technical Inspector
References:
TM 1-1520-238-T
Equipment Conditions:
Ref
Condition
1.57
Helicopter safed
2.2
Access panel R200 removed
NOTE
This task is typical for all three circuit
breakers.
9.28.3. Removal
a. Enter pilot station (para 1.56). Observe all
safety precautions.
b. On pilot aft circuit breaker panel, open six
POWER circuit breaker.
c. Remove wire clamp (1) from rear of electrical
test panel (2).
(1) Remove nut (3).
(2) Remove screw (4) and washer (5) from clamp
(1).
(3) Remove clamp (1).
GO TO NEXT PAGE
M04-1316-1
M04-1316-2
4
5
1
3
2