TM 1-1520-238-23
9-102
Change 6
9.27.
AC GENERATOR NO. 2 REMOVAL/INSTALLATION continued
f. Check wires for wear, cuts, breaks, and damaged terminal lugs (para 9.1).
g. Check phenolic terminal stud mounting block for cracks, damaged threads, and arcing burns. None
allowed.
h. Check connectors for cracks, broken connections, bent pins, or damaged threads (para 9.1).
i. Check wiring harness for frayed insulation or other damage. None allowed.
j. Check power feeder wires for any chafing damage between the No. 1 generator and the electrical
power distribution box (para 9.1).
k. Check generator drive spline gear and spline adapter for damage and wear. None allowed.
l. Check generator seal on spline adapter for seepage. None allowed.
m. Check inner teeth on spline adapter for deformations and/or loss of material. None allowed.
n. Check cork stopper for oil seepage. None allowed.
(1) If seepage is present replace cork stopper. (para 6.72A).
o. Check identification plate for legibility, deformation, and security of attachment to housing.
GO TO NEXT PAGE