TM 1-1520-238-23
9-117
9.32.
TRANSFORMER-RECTIFIER NO. 2 REMOVAL/INSTALLATION continued
d. Check for ground at connector P12 (1) pin D
and negative terminal lugs (8). Use multimeter.
e. Attach connector P12 (1) on transformer-recti-
fier (3).
(1) Attach connector P12 (1) to receptacle
(P52)J1 (3).
(2) Lockwire connector P12 (1) to bolt (15). Use
wire (item 222, App F).
f. Attach four wires (4) to positive and negative
terminals (5) of transformer-rectifier (2).
(1) Install identified terminal lugs (8), two lock-
washers (7), and nuts (6) on terminals (5).
g. Inspect (QA).
h. Perform DC power generation maintenance
operational check (TM 1-1520-238-T).
i. Install access panel R200 (para 2.2).
END OF TASK
M04-1097-12
15
1
3
M04-1097-7
7
8
6
5
4
2